MT/B

MT/B
Hydraulic motor with integrated Brake is the MT/B Brake Motor. These motors have disc valve. The distributor valve has been separated from the output shaft and is driven by short cardan shaft. A balance plate counterbalances the hydraulic forces around the distributor valve. It gives the motor high efficiency even at high pressures and good starting characterstics. The Gerotor set have teeth fitted with rollers. The rollers reduce local stress and the tangential reaction forces on the rotor reducing friction to a minimum. This gives long operating life and better efficiency even at continuous high pressures.
Options
  • Fully integrated friction disc brake.
  • Side ports.
  • Shafts: Straight, Splined or Tapered.
  • Ports: BSPP
  • Other special features
MT/B
MT/B Displacement Max. speed Max. Torgue Max. Output Max. Pressure Drop Max. Oil Flow
cm3/rev [in3/rev] RPM daNm [lb-in] kW [HP] bar [PSI] l/min [GPM]
cont. int* cont. int* cont. int* cont. int* cont. int*
MT/B 160 161,1 [9.83] 625 780 47[4160] 56[4960] 26,5[36] 32[43] 200[2900] 240[3450] 100[26.5] 125[33]
MT/B 200 201,4 [12.29] 625 750 59[5220] 71[6385] 33,5[45] 40[54] 200[2900] 240[3450] 125[33] 150[40]
MT/B 250 251,4 [15.36] 500 600 73[6460] 88[7790] 33,5[45] 40[54] 200[2900] 240[3450] 125[33] 150[40]
MT/B 315 326,3 [19.9] 380 460 95[8410] 114[10090] 33,5[45] 40[54] 200[2900] 240[3450] 125[33] 150[40]
MT/B 400 410,9[25.06] 305 365 108[9560] 126[11150] 30[40] 35[45] 180[2600] 210[3050] 125[33] 150[40]
MT/B 500 523,6[31.95] 240 285 122[10800] 137[12125] 26,5[36] 30[40] 160[2300] 180[2600] 125[33] 150[40]
* Intermitten operation: the permissible values may occur for max. 10% of every minute
Brake’s specification data
Static Torque of Brake daNm [lb-in] 55 [4868]
Min. Brake Release Pressure*** bar [PSI] 143 [12657]
Max. Opening Presure bar [PSI] 280 [24782]
*** Motor-brakes must always have a drain line. The brake release pressure is the difference between the pressure in the brake release line and the pressure in the drain line.
Generel
Pressure fluid Mineral based-HLP(DIN 51524) or HM(ISO 6743/4)
Temperature range °C 40 – 140
Optimal Viscosity range (mm2/s ) 20 – 75
Filtration ISO code 20/16 (Min. recommended fluid filtration of 25 micron )