These motors have spool valve. The distributor valve has been integrated with the output shaft. The Gerotor set have plain teeth. These types of motors are suitable for long operating periods at moderate pressures or short operating periods at high pressures.
Options
- With or Without flange.
- Side or Rear ports.
- Series with pressure valve(s).
- Shafts: Straight or Splined.
- Ports: Metric or BSPP
- Speed sensoring.
- Other special features.
Parameters
MM | |||||||||||
MM | Displacement | Max. speed | Max. Torgue | Max. Output | Max. Pressure Drop | Max. Oil Flow | |||||
[cm3/rev] | [RPM] | [daNm] | [kW] | [bar] | [Ipm] | ||||||
cont. | int* | cont. | int* | cont. | int* | cont. | int* | cont. | int* | ||
MM 8 | 8,2 | 1950 | 2440 | 1,1 | 2,1 | 1,8 | 2,6 | 140 | 200 | 16 | 20 |
MM 12,5 | 12,9 | 1550 | 1940 | 1,6 | 2,3 | 2,4 | 3,2 | 140 | 200 | 20 | 25 |
MM 20 | 20 | 1000 | 1250 | 2,5 | 3,5 | 2,4 | 3,2 | 140 | 200 | 20 | 25 |
MM 32 | 31,8 | 630 | 790 | 4 | 5,7 | 2,4 | 3,2 | 140 | 200 | 20 | 25 |
MM 40 | 40 | 500 | 625 | 4,1 | 5,7 | 1,8 | 3 | 110 | 140 | 20 | 25 |
MM 50 | 50 | 400 | 500 | 4,5 | 5,8 | 1,7 | 2,1 | 90 | 125 | 20 | 25 |
* Intermitten operation: the permissible values may occur for max. 10% of every minute
Working conditions | |
Pressure fluid | Mineral based-HLP(DIN 51524) or HM(ISO 6743/4) |
Temperature range °C | 40 – 140 |
Optimal Viscosity range (mm2/s ) | 20 – 75 |
Filtration | ISO code 20/16 (Min. recommended fluid filtration of 25 micron ) |