These motors have spool valve. The distributor valve has been integrated with the output shaft. The Gerotor set have teeth fitted with rollers. The rollers reduce local stress and the tangential reaction forces on the rotor reducing friction to a minimum. This gives long operating life and better efficiency even at continuous high pressures.
Options
- Flange mount.
- Shafts: Straight, Splined or Tapered.
- Ports: Metric or BSPP.
- Other special features.
MH | |||||||||||
MH | Displacement | Max. speed | Max. Torgue | Max. Output | Max. Pressure Drop | Max. Oil Flow | |||||
[cm3/rev] | [RPM] | [daNm] | [kW] | [bar] | [Ipm] | ||||||
cont. | int* | cont. | int* | cont. | int* | cont. | int* | cont. | int* | ||
MH 200 | 201,3 | 370 | 445 | 51 | 58 | 16 | 18,5 | 175 | 200 | 75 | 90 |
MH 250 | 252 | 295 | 350 | 61 | 70 | 16 | 18,5 | 175 | 200 | 75 | 90 |
MH 315 | 314,9 | 235 | 285 | 74 | 82 | 14 | 15,5 | 175 | 200 | 75 | 90 |
MH 400 | 396,8 | 185 | 225 | 84 | 98 | 12,5 | 15 | 155 | 190 | 75 | 90 |
MH 500 | 502,4 | 150 | 180 | 82 | 104 | 11 | 14 | 125 | 160 | 75 | 90 |
* Intermitten operation: the permissible values may occur for max. 10% of every minute
Working Conditions | |
Pressure fluid | Mineral based-HLP(DIN 51524) or HM(ISO 6743/4) |
Temperature range °C | 40 – 140 |
Optimal Viscosity range (mm2/s ) | 20 – 75 |
Filtration | ISO code 20/16 (Min. recommended fluid filtration of 25 micron ) |