MT

MT
These motors have disc valve. The distributor valve has been separated from the output shaft and is driven by short cardan shaft. A balance plate counterbalances the hydraulic forces around the distributor valve. It gives the motor high efficiency even at high pressures and good starting characterstics. The Gerotor set have teeth fitted with rollers. The rollers reduce local stress and the tangential reaction forces on the rotor reducing friction to a minimum. This gives long operating life and better efficiency even at continuous high pressures.
Options
  • Flange and Wheel mount.
  • Short motor.
  • Tacho connection
  • Speed sensoring.
  • Side or Rear ports.
  • Shafts: Straight, Splined or Tapered
  • Ports: Metric or BSPP.
  • Other special features.
MT
MT Displacement Max. speed Max. Torgue Max. Output Max. Pressure Drop Max. Oil Flow
[cm3/rev] [RPM] [daNm] [kW] [bar] [Ipm]
cont. int* cont. int* cont. int* cont. int* cont. int*
MT 160 161,1 622 775 47 56 26,5 32 200 240 100 125
MT 200 201,4 620 752 59 71 33,5 40 200 240 125 150
MT 250 251,8 496 601 73 88 33,5 40 200 240 125 150
MT 315 326,3 382 461 95 114 33,5 40 200 240 125 150
MT 400 410,9 304 368 108 126 30 35 180 210 125 150
MT 500 523,6 238 289 122 137 26,5 30 160 180 125 150
MT 630 631,5 197 234 130 148 24,3 27,5 140 160 125 150
MT 725 724,3 172 209 127 147 20,2 26,8 120 140 125 150
* Intermitten operation: the permissible values may occur for max. 10% of every minute
Working Conditions
Pressure fluid Mineral based-HLP(DIN 51524) or HM(ISO 6743/4)
Temperature range °C 40 – 140
Optimal Viscosity range (mm2/s ) 20 – 75
Filtration ISO code 20/16 (Min. recommended fluid filtration of 25 micron )